Sign In | Join Free | My enlightcorp.com |
|
Brand Name : AI
Model Number : CFL
Certification : ISO
Place of Origin : China
MOQ : 1 Set Underground Cable Fault Detector
Price : Negotiable
Payment Terms : T/T, Western Union, L/C
Supply Ability : 100 sets per month
Delivery Time : 15 days
Packaging Details : Underground Cable Fault Detector packed in Plywood case
Power supply : AC220V±10%,45~65Hz
Maximum detect distance : 30M
Voltage measuring range : 0~35KV
Keyword : Cable Fault Detector,cable fault finder
Warranty : 1 Year
Size : 225*165*125mm
Weight : 2KG
Power consumption : 5VA
I. Introduction:
The normal operation of cable-communication and electric transport completely rely on the good condition of the cable-circuit. Once the circuit breaks down and without punctually examination and repairing, it will no doubt trigger the ass economic loss and bad social influence. So the cable fault detector is a very important tool.
This cable fault finder uses multiple testing methods and adopts the most advanced electronic devices and with computer and special electronic technology, combining our company’s successful experience of long-time exploitation on cable-fault measuring instruments, and it is absolutely of high tech, intelligence and abundant functions.
Our cable fault finding equipment is a testing device of good integrity. It can test on the High Resistance Flashover Fault, Grounding High and Low Resistance Fault, Short & Off Circuit on the Cable Fault and Poor contact and etc. If being equipped with sounding method and locating instrument, it can exactly detect the fault point. Furthermore, it especially applies for testingvarious power cable and communication cable.
II. Functions
1 | Maximum detect distance | 30km |
2 | Detect resolution | 1m |
3 | Power supply of cable fault detector | AC220V±10%,45~65Hz(it also has battery inbuilt) |
4 | Sample rate of impulse signal | 100MHz |
5 | Voltage series of cable | low voltage power cable(0~1kV), high voltage power cable(1kv~35kv), communication cable |
6 | Fault type can be detected | Disconnection of power cable, low insulation of power cable( High voltage impulse generator is required), low resistance and high resistance connected to earth , poor contact of connectors |
7 | Storage | 100 groups record |
8 | Power consumption | 5VA |
9 | Voltage divider ratio | 100:1 |
10 | Size | 225*165*125mm |
11 | Weight | 2KG |
12 | Working temperature | 0~50℃ |
Diagram of High Voltage Impulse Test Mode
![]() |
35KV Underground Cable Fault Detector Equipment For Cable Fault Finding Images |